H3CR-A Solid-State Timer

FOB Reference Price:Get Latest Price
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Zhejiang, China (Mainland)
Brand Name:
CHMY
Model Number:
H3CR-A Solid-State Timer

Specifications

Voltage:AC110V-220V50/60Hz DC24v
contact:Timed SPDT.inst.SPDT.
Timing Range:0.5S.1S.5S.10S.30S.60S.
3M.5M.10M.30M.

Part number H3CR-AH3CR-ASH3CR-A8H3CR-A8EH3CR-A8S
Rated supply voltage 100to240VAC 50/60Hz
24DC/AC
24DC/AC100to240VAC 50/60Hz
24DC/AC
24DC/AC
Operating voltage 85to 110% of rated supply voltage
Power consumption H3CR-A/A8 *100-240VAC 2.5W 24VDC/AC 2W
H3CR-A8E *100-240VAC 3W 24VDC/AC 2.5W
H3CR-AS/A8S *24VDC/AC 1W
Operating mode A:ON-delay
B:Repeat-cycle OFF start
B2:Repat-cycle ON start
C:Signal ON/OFF-delay
D:Signal OFF-delay
E:Interval
A:ON-delay (power supply start)
B2:Repeat-cycle ON start (power supply start)
E:Interval (power supply start)
J:One-shot(power supply start)
Part number H3CR-AH3CR-A8H3CR-A8EH3CR-AS/A8S
Control  output Time limit SPDT(2C)SPDT(1C)Open collector solid-state
InstantaneousSPDT(1C)
Output Max.Load 3A,250VAC(p.f=1)100 mA max.30VDC
Output Min.load 10 mA,5VDC
Repeat accuracy ±0.3%FS max.(0.3%10ms max.in a range of 1.2 s)
Setting error ±5% FS ±50 ms
Variation due to voltage change ±0.5%FS max.(±0.5% ±10ms max.in a range of 1.2s)
Variation due to temperature change ±2%FS max.(±2% ±10ms max.in a range of 1.2s)
Power reset Minimum power-opening time:0.1s
Mounting method DIN track mounting,surface mounting,and flush mounting
Connection11-pin(H3CR-A/AS),8-pin(H3CR-A8)
Ambient emperature Operating -10-55 with no icing
Ambient temperature Storage -25-65 with no icing
Ambient humidity Operating 35 to 85%RH
Insulaton resistance 100MΩ min.(at DC500VDC)
Dielectric strength 2000V 50/60Hz min between curren-carying and non-curent-carrying parts and between contact and control circuit
1500V 50/60Hz min between control output terminals and operating circuit
1000V 50/60Hz min Between contacts
Static immunity Malfunction:8 KV Destruction:15KV
Impulse withstand voltage 3KV(between power terminals)1KV for 24DC
4.5KV(between current-carrying terminal and exposed non-current-carrying metal parts)1.5KV for 24VDC
VibrationMechanical durability 10 to 55 Hz with 0.75-mm double amplitude each in 3 directions
Malfunction durability 10 to 55 Hz with 0.5-mm double amplitude each in 3 directions
ShockMechanical durability30G
Malfunction durability 10G
Service life Mechanical10 million operations minimum(under no load,at 1,800 operations/hour)
Electrical100,000 operations minmum at maximum ratings
Degree of protection TECIP40(panel surface)
WeightApprox:100g